الوصف
There are five suggested designs (configurations) for the current Steam plant (Reheating cycle, Regeneration with a single open feedwater heater, Regeneration with closed feedwater heater, Regeneration with closed feedwater heater and pumped condensate and Rehating and are closed feedwater heater ), while one suggested design for the current gas plant (Combined cycle).
Obtained results were good in terms of reducing gas emissions polluting and in terms of increased efficiency. Whereas, the combined cycle gave a high efficiency, lesser amount of energy and money losses than other configurations. Efficiency of the combined cycle process reaches 44%. This development on the current stations is reflected positively on the environment as this will reduce
gas emissions as a result of decreasing the heating rate. Whereas using combined cycle leads to reduction of gaseous emission; (SO2 reduced up to 100%, VOC's reduced up to 100 % ,CO2 reduced up to 75.8%, and, NOx reduced up to 20%).
الكلمات الدالة