مشروع البحث:
Comparison study between STATCom Static Synchronous Compensator and SSSC Static Syncgronous Series compensator

dc.contributor.advisorد. عمر جمعة امريحيل
dc.date.accessioned2025-03-09T08:11:08Z
dc.date.available2025-03-09T08:11:08Z
dc.descriptionThe aim of this thesis is to give a comparison study between two very important and recent shunt /series FACTS devices, which are, Static Synchronous Compensator STATCOM and Static Synchronous Series Compensator SSSC. The study discus and compare the modeling, connection, location of both devices in power network, and their applications to solving power system problems, such as, power flow control, increase of transmission capability, voltage control, as well as the impact of these devices to improve system stability was analyzed when a three phase fault is applied. Also the capability of the system to operate when one element is out of service was tested in the presence of these devices. In addition, the Critical Clearing Time CCT of the system with and without FACTS devices was determined, the IEEE 14 bus was selected to performed this study by using (PSAT software). The results showed that the STATCOM is better than SSSC for voltage regulation, while the SSSC is best in core of controlling the flow of power and damping out the oscillation.
dc.description.abstractThe aim of this thesis is to give a comparison study between two very important and recent shunt /series FACTS devices, which are, Static Synchronous Compensator STATCOM and Static Synchronous Series Compensator SSSC. The study discus and compare the modeling, connection, location of both devices in power network, and their applications to solving power system problems, such as, power flow control, increase of transmission capability, voltage control, as well as the impact of these devices to improve system stability was analyzed when a three phase fault is applied. Also the capability of the system to operate when one element is out of service was tested in the presence of these devices. In addition, the Critical Clearing Time CCT of the system with and without FACTS devices was determined, the IEEE 14 bus was selected to performed this study by using (PSAT software). The results showed that the STATCOM is better than SSSC for voltage regulation, while the SSSC is best in core of controlling the flow of power and damping out the oscillation.
dc.identifier6961
dc.identifier.urihttps://dspace.academy.edu.ly/handle/123456789/1425
dc.subjectComparison study between STATCom Static Synchronous
dc.titleComparison study between STATCom Static Synchronous Compensator and SSSC Static Syncgronous Series compensator
dspace.entity.typeProject
project.endDate2019
project.funder.nameهندسة الحاسوب
project.investigatorعبد القادر امحمد مفتاح مربيط
project.startDate2018
relation.isOrgUnitOfProjectd70558aa-ae49-4279-9e5d-a763f40a7531
relation.isOrgUnitOfProject.latestForDiscoveryd70558aa-ae49-4279-9e5d-a763f40a7531
الملفات
الحزمة الأصلية
يظهر اﻵن 1 - 1 من 1
لا توجد صورة مصغرة متاحة
اﻻسم:
Comparison study between STATCOM Static ‎Synchronous Compensator and SSSC Static ‎Synchronous Series Compensator‎.pdf
الحجم:
3.7 MB
التنسيق:
Adobe Portable Document Format
حزمة الترخيص
يظهر اﻵن 1 - 1 من 1
لا توجد صورة مصغرة متاحة
اﻻسم:
license.txt
الحجم:
1.71 KB
التنسيق:
Item-specific license agreed to upon submission
الوصف: