dc.description | The aim of this thesis is to give a comparison study between two very important and recent shunt /series FACTS devices, which are, Static Synchronous Compensator STATCOM and Static Synchronous Series Compensator SSSC. The study discus and compare the modeling, connection, location of both devices in power network, and their applications to solving power system problems, such as, power flow control, increase of transmission capability, voltage control, as well as the impact of these devices to improve system stability was analyzed when a three phase fault is applied. Also the capability of the system to operate when one element is out of service was tested in the presence of these devices. In addition, the Critical Clearing Time CCT of the system with and without FACTS devices was determined, the IEEE 14 bus was selected to performed this study by using (PSAT software). The results showed that the STATCOM is better than SSSC for voltage regulation, while the SSSC is best in core of controlling the flow of power and damping out the oscillation. | |
dc.description.abstract | The aim of this thesis is to give a comparison study between two very important and recent shunt /series FACTS devices, which are, Static Synchronous Compensator STATCOM and Static Synchronous Series Compensator SSSC. The study discus and compare the modeling, connection, location of both devices in power network, and their applications to solving power system problems, such as, power flow control, increase of transmission capability, voltage control, as well as the impact of these devices to improve system stability was analyzed when a three phase fault is applied. Also the capability of the system to operate when one element is out of service was tested in the presence of these devices. In addition, the Critical Clearing Time CCT of the system with and without FACTS devices was determined, the IEEE 14 bus was selected to performed this study by using (PSAT software). The results showed that the STATCOM is better than SSSC for voltage regulation, while the SSSC is best in core of controlling the flow of power and damping out the oscillation. | |
dc.identifier | 6961 | |
dc.identifier.uri | https://dspace.academy.edu.ly/handle/123456789/1425 | |
dc.subject | Comparison study between STATCom Static Synchronous | |
dc.title | Comparison study between STATCom Static Synchronous Compensator and SSSC Static Syncgronous Series compensator | |
dspace.entity.type | Project | |
project.endDate | 2019 | |
project.funder.name | هندسة الحاسوب | |
project.investigator | عبد القادر امحمد مفتاح مربيط | |
project.startDate | 2018 | |
relation.isOrgUnitOfProject | d70558aa-ae49-4279-9e5d-a763f40a7531 | |
relation.isOrgUnitOfProject.latestForDiscovery | d70558aa-ae49-4279-9e5d-a763f40a7531 |
الملفات
الحزمة الأصلية
1 - 1 من 1
لا توجد صورة مصغرة متاحة
- اﻻسم:
- Comparison study between STATCOM Static Synchronous Compensator and SSSC Static Synchronous Series Compensator.pdf
- الحجم:
- 3.7 MB
- التنسيق:
- Adobe Portable Document Format
حزمة الترخيص
1 - 1 من 1
لا توجد صورة مصغرة متاحة
- اﻻسم:
- license.txt
- الحجم:
- 1.71 KB
- التنسيق:
- Item-specific license agreed to upon submission
- الوصف: