مشروع البحث:
Exergy analysis of a 10000m3/ day swro desalination plant in tajoura

dc.contributor.advisorد.محمد صالح البوراوي
dc.date.accessioned2026-06-14T07:32:03Z
dc.date.available2026-06-14T07:32:03Z
dc.descriptionExergy analysis is a method that uses the mass and energy conservation principles together with the second law of thermodynamics (entropy equations) in order to identify the magnitudes and the locations of real energy losses, in order to improve the existing systems, processes or components. The seawater reverse osmosis (SWRO) plant of Tajoura Nuclear Research Center was analyzed thermodynamically using actual plant data. Exergy flow rates are calculated all over the plant. The rates of exergy destruction and their percentages are determined so that the sites of highest exergy destruction can simply be recognized. The highest exergy destruction (48.32 %) happens in the 1st stage high pressure pump (HPP), followed by the exergy destruction in the mixing point at the suction side of the 1st HPP (around 15.46 %). The next largest exergy destruction are the 1st and 2nd membranes modules which is (11.83 %) and (12.06%) respectively, of the total input exergy, the remaining (12.33) % of exergy destruction is distributed among intake transfer pumps (2.996%), filtration unit (3.23%), Turbine (2.01%), 2nd HPP (2.26%) and 2nd stage throttling valve (concentrate) (1.83%). The second law efficiency of the plant was 25.65 % using the old style turbine and high energy consumption membranes. This shows that chances of development might be using a new membranes with high production rate and low energy consumption to reduce exergy destruction and make the plant operation more cost effective. Moreover, other things was taken into account for increasing the efficiency of the plant through the use of high efficiency pump motors with a variable frequency drive (VFD) and the replacement of the traditional Old Turbine and throttling valves with developed energy recovery devices (ERD) such as pressure exchangers (PX).
dc.description.abstractExergy analysis is a method that uses the mass and energy conservation principles together with the second law of thermodynamics (entropy equations) in order to identify the magnitudes and the locations of real energy losses, in order to improve the existing systems, processes or components. The seawater reverse osmosis (SWRO) plant of Tajoura Nuclear Research Center was analyzed thermodynamically using actual plant data. Exergy flow rates are calculated all over the plant. The rates of exergy destruction and their percentages are determined so that the sites of highest exergy destruction can simply be recognized. The highest exergy destruction (48.32 %) happens in the 1st stage high pressure pump (HPP), followed by the exergy destruction in the mixing point at the suction side of the 1st HPP (around 15.46 %). The next largest exergy destruction are the 1st and 2nd membranes modules which is (11.83 %) and (12.06%) respectively, of the total input exergy, the remaining (12.33) % of exergy destruction is distributed among intake transfer pumps (2.996%), filtration unit (3.23%), Turbine (2.01%), 2nd HPP (2.26%) and 2nd stage throttling valve (concentrate) (1.83%). The second law efficiency of the plant was 25.65 % using the old style turbine and high energy consumption membranes. This shows that chances of development might be using a new membranes with high production rate and low energy consumption to reduce exergy destruction and make the plant operation more cost effective. Moreover, other things was taken into account for increasing the efficiency of the plant through the use of high efficiency pump motors with a variable frequency drive (VFD) and the replacement of the traditional Old Turbine and throttling valves with developed energy recovery devices (ERD) such as pressure exchangers (PX).
dc.identifier5770
dc.identifier.urihttps://dspace.academy.edu.ly/handle/123456789/2288
dc.subjectالهندسة الكيمائية والنفط
dc.titleExergy analysis of a 10000m3/ day swro desalination plant in tajoura
dspace.entity.typeProject
project.endDate2015
project.funder.nameالتطبيقية والهندسية
project.investigatorاسامة احمد سليمان الزقنى
project.startDate2014
الملفات
الحزمة الأصلية
يظهر اﻵن 1 - 1 من 1
لا توجد صورة مصغرة متاحة
اﻻسم:
رسالة الطالب أسامة أحمد الزقني.pdf
الحجم:
2.38 MB
التنسيق:
Adobe Portable Document Format
حزمة الترخيص
يظهر اﻵن 1 - 1 من 1
لا توجد صورة مصغرة متاحة
اﻻسم:
license.txt
الحجم:
1.71 KB
التنسيق:
Item-specific license agreed to upon submission
الوصف: